								| Temperature range | fixed -20°C …+60°C flexing 0°C …+50°C | 
| Bending radius | fixed min. 4 x D flexing min. 8 x D | 
| Tensile strength Crushing strength Impact strength | max. 60 N min. 1000 N/10 cm min. 10 impacts | 
| Conductor resistance Resistance imbalance | max. 150 Ω/km max %3 | 
| Insulation resistance min. Capacitance Capacity imbalance Rated impedance Velocity of propagation Propagation delay Signal delay | min. 5000 MΩ x m nom. 50 pF/m max. 1600 pF/km 100 ± 5 Ω @100 MHz 67-69% max. 537 ns/100 m max. 45 ns/100 m | 
| Test voltage | 1000 V | 
| Operating voltage max. TCL min. Coupling attenuation Segregation class | max 72 V “Level 2” “Type III” “b” EN 50174-2 | 
| Standards | ISO/IEC 11801 2nd ed., IEC 61156-5 EN 50173-1, EN 50288-3-1 ANSI EIA/TIA 568-C.2 | 
| Fire performance | Vertical flame propagation EN 60332-1-2 (LSZH-PVC) Corrosive gas EN 60754-1/2 (LSZH) Smoke density EN 61034-2 (LSZH) | 
| EU declaration of conformity | LVD Low Voltage Directive 2014/35/EU RoHS Restriction of Hazardous Substances 2011/65/EU | 
This data cable range is designed for analogue and digital signal transmission in audio, video and data applications in data communication systems supporting 100 MHz, 1.0 Gbit/s 1 Gigabit Ethernet. Cables meet the requirements of structural cabling standards including ANSI EIA/TIA 568, ISO/IEC 11801 and EN 50173 Class D. IEEE 802.3:10Base-T; 100Base-T; 1000Base-T IEEE 802.5 16 MB; ISDN; TPDDI; ATM Power over Ethernet (PoE) / PoE+
Conductor Stranded electrolytic copper wire, Ø 26/7AWG
Insulation HDPE, in compliance with TIA 568 insulation colour coding 80°C, EN 50290-2-23 Sheath LSZH/LS0H – RAL 1015 Cream, Ø 5.0 mm 70°C, EN 50290-2-27 PVC – RAL 7001 Grey, Ø 5.0 mm TM52 70°C, EN 50290-2-22